• HomeTutior
  • AEGISPlatform
  • How it worksPlatform
  • DeploymentPlatform
  • CollectionPlatform
  • DetectionPlatform
  • AI analystPlatform
  • Triage and incidentsPlatform
  • Case managementPlatform
  • ResponsePlatform
  • Threat intelligencePlatform
  • ReportingPlatform
  • Audit recordPlatform
  • Access controlPlatform
  • Data handlingPlatform
  • How it is builtPlatform
  • The consolePlatform
  • Product tourPlatform
  • IntegrationsPlatform
  • SecurityPlatform
  • Too many alertsSolutions
  • Too few analystsSolutions
  • Data that must staySolutions
  • Evidence for an auditSolutions
  • RansomwareSolutions
  • Account takeoverSolutions
  • TelecomSolutions
  • BankingSolutions
  • GovernmentSolutions
  • TestingServices
  • OperationsServices
  • CompareResources
  • Against a traditional SIEMResources
  • Against a cloud SOC platformResources
  • Against separate toolsResources
  • Why self-hostedResources
  • Moving from a SIEMResources
  • ExplainersResources
  • What a SIEM isResources
  • SIEM, SOAR and XDRResources
  • What OCSF isResources
  • What Sigma rules areResources
  • ATT&CK, explainedResources
  • What self-hosted meansResources
  • A buyer's checklistResources
  • CompanyCompany
  • ContactCompany
Menu

Platform / Collection

Every event normalised to one open format

Events reach AEGIS by push, pull or its own host collector, and a parser maps each one to OCSF. Rules, searches and the AI analyst read the same fields.

One set of fields for every rule

AEGIS normalises each event to one of 18 OCSF classes. Rules, searches and the AI's tools all read the same promoted fields: user, host, source and destination address, destination domain, process, parent process, command line, file path, SHA-256, bytes out and status.

Values that belong to one class go to a map of attributes beside them. Each event keeps two times: its own, and the time intake received it.

The routes in

RouteHow it arrivesHow the sender is identified
HTTPS pushA JSON array or object posted to the events endpoint, optionally gzip-compressedA per-tenant ingest key in a request header
WebhookOne path per source; the source name hints which parser appliesThe same per-tenant ingest key
Syslog over TLSRFC 5425 on port 6514The client certificate, pinned by fingerprint, selects the tenant
Plain syslogUDP on port 5140, with optional TCP, on a private networkThe sender's registered network selects the tenant
API pullAEGIS polls a service's API with paging, cursors and a circuit breakerSet per collector; none runs until you configure it
Host collectorMutual TLS on port 8443, gzip-compressed, from a bounded on-disk queueA 30-day certificate the host renews by itself; intake takes the tenant and host id from it

An event's tenant is not read from the event.

From a raw record to a stored event

Decode

Syslog headers, RFC 5424 structured data, CEF, LEEF, key=value, CSV, embedded JSON and Windows XML fragments are decoded once. Syslog that is not UTF-8 is read as GB18030. Lines no parser claims pass through a fallback extractor for addresses, accounts, CVE identifiers and severity tokens, and the raw line is kept.

Parse

A parser claims the record and maps its fields. JSON, decoded-line and text parsers ship, including NetFlow/IPFIX, sFlow, APISIX, Kafka audit, MikroTik and Snowflake.

Deduplicate

Per tenant, an identical event repeated within five minutes is dropped.

Stamp

A threat-intelligence match on a source or destination address, a destination domain or a SHA-256 hash is stamped on the event and can raise its severity. External addresses also receive GeoIP country and ASN enrichment offline.

Store

The event is written to the lake by day, ordered by tenant and time.

85

Parsers in the pack that ships with the product.

AEGIS 0.3.4. 35 of them are marked experimental.
18

OCSF classes an event can be normalised to.

A record no parser can place becomes class 0, the OCSF Base Event

What your team does with it

Test a parser against your own record

In the parser editor an admin runs a record through a parser and sees the field diff and the match predicate that failed. A save needs every sample to pass, is audited, and applies to that tenant only.

Keep up to 100 custom parsers per tenant

Connector files reload within seconds of a change.

See what each source is sending

Data Sources shows each connector, its 24-hour volume and the parse rate of each source type.

Search with SQL, pipes or a question

The Query Center runs SQL, pipe-style queries, and plain-language questions that the model turns into SQL. The model receives the question and the schema, not event rows.

Every query is fenced to its tenant

Typed and model-proposed SQL pass the same read-only checks and run under a reader limited to the caller's tenant, capped at 60 seconds and 50,000 rows.

Watch each collector's health

A host collector sends a heartbeat every 60 seconds with its version, queue depth, send errors and per-input status. The Collectors page shows it as reporting, degraded, buffering or silent.

How long each kind of data is kept

DataDefaultDetail
Searchable events90 daysSet for the deployment, from 1 to 3,650 days
Hourly event counts400 daysCounts only, kept after the events themselves expire
Events and alerts in flight72 hoursOn the message bus
Entity graph180 daysCounted from when a link was last seen
Alerts, incidents, cases, investigations, audit recordsNo expiryKept until the tenant is purged

How parsers are tested

222 sample records

Every one of the 85 parsers ships with sample records, and each sample is run through real normalisation before a release. A parser that arrives without samples is refused.

An update is all or nothing

An invalid parser update is rejected whole, and the parsers already running keep running.

Alert feeds are not counted as telemetry

A parser for another product's alerts declares no ATT&CK data component, so coverage is not inflated by alerts someone else raised.

Common questions

What happens to a source that has no parser?

If the product sends CEF or LEEF, the generic parsers read it. Otherwise the record is still stored and its source type is listed as unclaimed, and an admin can write and test a parser for it in the console.

What does a sender see when intake cannot publish?

An error that tells it when to retry. The batch's deduplication keys are released, so the retry is stored. Every batch response counts what was accepted, deduplicated, rejected and failed to publish.

Can a device with a self-signed certificate send syslog over TLS?

Yes. The certificate is pinned by its fingerprint. Deleting the source revokes it, and open connections close within about 60 seconds.

Can a compromised server send events as another tenant?

No. An enrolled collector's tenant and host id come from its certificate, and intake drops records that claim another. An admin can revoke a host, and intake refuses it within 60 seconds.

Does the host collector lose events when the server is unreachable?

It writes each event to a bounded on-disk queue before any checkpoint advances, retries with a backoff, and delivers at least once.

Read next.

Talk to an engineer

Tell us what you run today and what worries you. Someone who works on AEGIS will reply.

Get in touch